<span id="fpn9h"><noframes id="fpn9h"><span id="fpn9h"></span>
<span id="fpn9h"><noframes id="fpn9h">
<th id="fpn9h"></th>
<strike id="fpn9h"><noframes id="fpn9h"><strike id="fpn9h"></strike>
<th id="fpn9h"><noframes id="fpn9h">
<span id="fpn9h"><video id="fpn9h"></video></span>
<ruby id="fpn9h"></ruby>
<strike id="fpn9h"><noframes id="fpn9h"><span id="fpn9h"></span>
Volume 33 Issue 12
Jul.  2021
Turn off MathJax
Article Contents
GAN Chun-lei, LIU Xue-feng, HUANG Hai-you, XIE Jian-xin. Electrochemical corrosion performance of continuous columnar-grained BFe10-1-1 alloy[J]. Chinese Journal of Engineering, 2011, 33(12): 1492-1500. doi: 10.13374/j.issn1001-053x.2011.12.010
Citation: GAN Chun-lei, LIU Xue-feng, HUANG Hai-you, XIE Jian-xin. Electrochemical corrosion performance of continuous columnar-grained BFe10-1-1 alloy[J]. Chinese Journal of Engineering, 2011, 33(12): 1492-1500. doi: 10.13374/j.issn1001-053x.2011.12.010

Electrochemical corrosion performance of continuous columnar-grained BFe10-1-1 alloy

doi: 10.13374/j.issn1001-053x.2011.12.010
  • Received Date: 2011-06-27
    Available Online: 2021-07-30
  • The corrosion resistance of BFe10-1-1 alloy with continuous columnar-grained microstructure in a 3.5% NaCl solution was investigated by means of polarization tests and electrochemical impedance spectroscopy(EIS),and compared with that of BFe10-1-1 alloy with conventional polycrystalline microstructure fabricated by conventional casting.Polarization test results show that both BFe10-1-1 alloys have similar electrochemical behavior,and their polarization curves include three distinct regions,that is,the active dissolution region,the active-passive transition region and the limiting current region.However the corrosion rate of BFe10-1-1 alloy with continuous columnar-grained microstructure is lower than that of the one with conventional polycrystalline microstructure,as less microsegregation in BFe10-1-1 alloy with continuous columnar-grained microstructure can effectively avoid interdendritic corrosion.EIS spectra indicate that BFe10-1-1 alloy with continuous columnar-grained microstructure has a higher charge transfer resistance and a higher corrosion product film resistance compared with BFe10-1-1 alloy with conventional polycrystalline microstructure.The results further demonstrate that BFe10-1-1 alloy with continuous columnar-grained microstructure has a better corrosion resistance.

     

  • loading
  • 加載中

Catalog

    通訊作者: 陳斌, bchen63@163.com
    • 1. 

      沈陽化工大學材料科學與工程學院 沈陽 110142

    1. 本站搜索
    2. 百度學術搜索
    3. 萬方數據庫搜索
    4. CNKI搜索
    Article views (148) PDF downloads(32) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return
    <span id="fpn9h"><noframes id="fpn9h"><span id="fpn9h"></span>
    <span id="fpn9h"><noframes id="fpn9h">
    <th id="fpn9h"></th>
    <strike id="fpn9h"><noframes id="fpn9h"><strike id="fpn9h"></strike>
    <th id="fpn9h"><noframes id="fpn9h">
    <span id="fpn9h"><video id="fpn9h"></video></span>
    <ruby id="fpn9h"></ruby>
    <strike id="fpn9h"><noframes id="fpn9h"><span id="fpn9h"></span>
    www.77susu.com